Technical Guide

Reading IEC 60227 and IEC 60228: A Buyer’s Checklist

What IEC 60227 and IEC 60228 actually cover, which details to put on the purchase order, and how to avoid a cable that looks right but fails inspection.

Mining cable factory production line

IEC 60227 and IEC 60228 appear on many mining cable datasheets. They are related, but they do not cover the same thing. Knowing which standard applies to which part of the construction makes it easier to write a purchase order that can be checked.

IEC 60228: the conductor

IEC 60228 defines the nominal cross-sectional areas and the conductor classes for cables. Class 1 is a solid conductor, Class 2 is a stranded conductor for fixed wiring, and Class 5 is a flexible stranded conductor. The class affects termination, bending and the behaviour of the cable in a moving application.

When you specify a 1.5 mm² control core, state the conductor class. A Class 2 conductor and a Class 5 conductor are both 1.5 mm², but they are not interchangeable in every terminal or drag chain — and in a trailing cable the class is the difference between years of service and a fatigue failure.

IEC 60227: PVC-insulated cable

IEC 60227 covers polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V. For a 300/500 V control cable it provides the framework for insulation and sheath performance, dimensions and test requirements. The standard is not a single construction drawing; the actual core count, screen, armour and sheath are defined by the manufacturer’s datasheet and the purchase order.

Where the mining standards take over

IEC 60227 and IEC 60228 describe general cable construction. They do not cover flame retardancy, anti-static sheath properties or impact resistance for a coal face. For underground power and trailing cables, the construction is normally written against AS/NZS 1802 or the equivalent mine standard, with IEC 60228 still governing the conductor. Ask which standard governs which part — see the trailing and flexible rubber cable range for the constructions we build to AS/NZS 1802.

What to put on the purchase order

  • Product description and application.
  • Rated voltage, core count and cross-section.
  • Conductor class and material.
  • Insulation and sheath compound.
  • Screen type, coverage and drain wire.
  • Armour type and material.
  • Applicable standard and any site specification.
  • Core identification, length, drum marking and inspection requirements.

Check the datasheet against the order

A datasheet that says “IEC 60227” is a starting point, not a complete specification. Check the conductor class, the screen coverage, the sheath thickness and the temperature rating. Ask for the order-specific datasheet before production, and confirm that the test report matches the construction that will be shipped.

Buyer’s check: the standard defines the framework; the datasheet defines the product; the purchase order defines what you will receive. Make sure all three agree.

Our team can review a specification against the proposed construction and identify the details that need to be confirmed before the order is released. Send it with the route description from mining power cables and we will answer with a marked-up datasheet.